Product Description
|
Size
|
ODP1500:1480mm, ODP1200:1280mm
ODP900:980mm, ODP600:660mm |
|
Material
|
Cotton Yarn, Copper Wire, PET, etc
|
|
Voltage
|
220V 50~60Hz
|
|
Power Consumption
|
ODP1500:300w/m, ODP1200:240w/m
ODP900:200w/m, ODP600:120w/m |
Healthy Heating System
Cost-Saving Heating System
Safe Heating System
Clean Heating System
Product Structure

![]() |
Far Infrared-Ray Cotton Mesh Heating Material [Patent No. 0479509 This cotton mesh heating material is a new concept of heating material made by impregnating cotton yard with carbon, which emits a large amount of far infrared radiation. Radiates 91.0% far infrared ray (Korea Institute of Construction Materials) |
Applied Technologies
Specifications
|
Model Name
|
Dimension (Width X Thickness)
|
Power Consumption
|
Remark
|
|
ODP1500
|
1480mmX0.8mm
|
300W
|
|
|
ODP1200
|
1280mmX0.8mm
|
240W
|
|
|
ODP900
|
980mmX0.8mm
|
200W
|
|
|
ODP600
|
660mmX0.8mm
|
120W
|
Product Reliability Testing
Tests are conducted pursuant to the Standard Testing Method of Carbon Sheet Heating Material (RS L 0006) of the Korean Agency for Technology and Standards under the Ministry of Commerce, Industry, and Energy, by requesting a research center equipped with testing equipment and measuring instruments. The test results of this product are based on the test reports of the Korea Electric Testing Institute (Reliability 2010-0020, 2010.04.19).
|
Type
|
Checklist
|
Judging Criteria
|
Testing Method
|
Test Results
|
Remark
|
|
|
Performance Testing
|
Electrical Properties Testing
|
Line Resistance
|
Must be within a 10% range of 800ohm (720ohm~880ohm)
|
Measure using a resistance meter
|
Yes
|
Pass
|
|
Power Consumption
|
Must be below 10% of 60W (54W~66W)
|
Measure using a power consumption meter
|
Yes
|
Pass
|
||
|
Sheet Resistance Distribution Test
|
Difference between minimum and maximum must be within a 10% range
|
Measure resistance every 1cm
|
Yes
|
Pass
|
||
|
Heat Distribution Measuring Test
|
Difference between minimum and maximum must be within a 10% range
|
Measure temperature of the heating part at temperature of saturation
|
Yes
|
Pass
|
||
|
Environmental Testing
|
Withstanding Voltage Test
|
No insulation breakdown
|
Apply 2kV for a minute
|
Yes
|
Pass
|
|
|
Insulation Test
|
Must be 5Mohm and higher
|
Measure insulation resistance using a 500V insulation resistance meter
|
Yes
|
Pass
|
||
|
Humidity Resistance Test
|
Resistance variation must be below 15% of early performance
|
|
Yes
|
Pass
|
||
|
Thermal Shock Test
|
Resistance variation must be below 15% of early performance
|
|
Yes
|
Pass
|
||
|
Low Temperature Preservation Test
|
Resistance variation must be below 15% of early performance
|
|
Yes
|
Pass
|
||
|
Salt Water Spray Test
|
Resistance variation must be below 15% of early performance
|
|
Yes
|
Pass
|
||
Test Results
|
No.
|
Test Checklist
|
Test Method
|
Quality Standard
|
Test Results
|
Remark
|
|
1
|
Far Infrared Ray Emission Test
|
Korea Institute of Construction Materials KICM-FIR-1005
|
91% and higher
|
Yes
|
Pass
|
|
2
|
Tensile Strength Test
|
KS M3503-02
|
2538N/cm³, 847N/cm³
|
Yes
|
Pass
|
|
3
|
Antibacterial Test (E.coli, pyogenic bacteria)
|
Korea Institute of Construction Materials
|
83.3%, 87.2%
|
Yes
|
Pass
|